    Building wire (THHN, THWN-2, XHHW-2), service cable (SER, USE-2, UF-B), MC cable, and conduit (EMT, IMC, RMC, PVC 40/80, FMC, LFMC) from Southwire, Encore, Cerrowire, General Cable, and Priority Wire — cut-to-length or full-reel, contractor pricing.

    Wire and conduit distribution — insulation type vs application, conduit type vs environment
    PES Distribution — Full Electrical Supply House
    Direct distributor for Square D, Eaton, GE, Siemens, Schneider Electric, Milbank, Cutler-Hammer, ABB, Allen-Bradley, Hubbell, Leviton, Bryant, Wiegmann, Hoffman, and 155 more authorized brands — 85,000+ SKUs across breakers, panels, transformers, wire, conduit, motor controls, and switchgear. Contractor pricing, net-30 terms, will-call pickup at our Louisville, KY warehouse. Registered contractors get take-off tools, load calcs, and voltage-drop sizing inside the PES contractor portal.

    Wire and conduit is where a contractor's margin gets made or lost. Every 1000 ft of wire and every 100 ft of conduit is a real dollar delta between authorized-channel and grey-market inventory, and every job prices differently by copper spot, aluminum spot, mill lead times, and freight class. PES Distribution stocks the working inventory of the four major building-wire mills — Southwire, Encore Wire, Cerrowire, and General Cable / Prysmian — plus Priority Wire & Cable and Nassau for the specialty lines. Conduit is Wheatland, Allied, Republic, JM Eagle, Cantex, and Carlon. Every SKU is manufacturer-verified with a mill test report on request.

    3,000+
    Wire & cable SKUs
    1,800+
    Conduit + fittings SKUs
    14 AWG – 1000 kcmil
    Building-wire range
    1/2" – 6"
    Conduit trade sizes

    Building wire insulation types — THHN, THWN-2, XHHW-2

    All modern branch and feeder wiring in a raceway uses one of three insulation types: THHN, THWN-2, or XHHW-2. In practice, most cable is dual- or triple-rated (a jacket printed 'THHN/THWN-2' works in dry or wet conduit; a 'XHHW-2/USE-2' can be direct-buried too). Match the insulation rating to the wettest environment the wire will ever see — NEC 310.10(B/C) requires wet-location insulation anywhere raceway goes outdoors, underground, or through a concrete slab.

    Insulation type Max temp — dry Max temp — wet Approved applications Typical use
    THHN 90 °C — (dry only) Dry conduit, indoor branch/feeder Interior EMT runs
    THWN 75 °C 75 °C Dry or wet conduit General wet-conduit branch (older listings)
    THWN-2 90 °C 90 °C Dry or wet conduit; nylon jacket Modern default — replaces THHN and THWN
    XHHW 90 °C 75 °C Dry or wet conduit; crosslinked polyethylene Feeder, service
    XHHW-2 90 °C 90 °C Dry or wet conduit; crosslinked, no nylon Modern feeder / service default
    USE-2 90 °C 90 °C (direct burial) Direct burial, wet, service entrance Underground service laterals
    RHW-2 90 °C 90 °C Dry or wet; thicker insulation Rare — legacy commercial spec

    ⚠ The wet-location ampacity trap: THHN in a wet raceway is limited to the 75 °C column.

    Marked 'THHN/THWN-2' cable is rated 90 °C in dry conduit and 90 °C in wet conduit. Marked THHN-only cable cannot be used in wet locations at all. If your conduit run passes outdoors, underground, or under a slab, spec THWN-2, XHHW-2, or USE-2 — not straight THHN. Inspectors write this up in Kentucky and Ohio routinely.

    Cable assemblies — SER, SEU, MC, NM-B, UF-B, PV

    Cable assemblies bundle multiple insulated conductors under a single jacket — faster to pull than individual conductors in conduit and required by code in specific applications (residential branch wiring under NEC 334.10, health-care under 517).

    Assembly Ampacity basis Approved use Typical brand + prefix
    NM-B (Romex) 60 °C column (NEC 334.80) Dry, indoor residential branch — walls / attic / joists Southwire, Encore, Cerro
    SER / SEU 75 °C column Service entrance (SEU = weather-exposed; SER = interior sub-feed) Southwire, Encore, Cerrowire
    UF-B (underground feeder) 60 °C column when direct-buried Direct burial, wet, sunlight-resistant Southwire, Cerrowire
    USE-2 90 °C column direct-buried Underground service lateral, wet-approved Encore, Priority Wire
    MC Cable (Type MC) 75 °C column standard, 90 °C if XHHW-2 Commercial dry/damp interior, feeder + branch Southwire AFC/MC-Cable, AFC Cable Systems
    MC-HL (Hazardous Location) 75 °C column Class I Div 2 hazardous locations AFC MC-HL, Prysmian MC-HL
    Armored (AC) cable 60 °C column Interior dry — light commercial, some AHJs require MC over AC AFC AC-90, Southwire
    PV Wire (PV / USE-2) 90 °C column, 105 °C listed PV DC circuits, exposed to sun and weather Southwire, General Cable Suprashield
    Tray Cable (TC-ER) 90 °C column dry / 75 °C wet Cable tray, exposed free-air runs Southwire, General Cable

    When to use MC cable vs conduit-and-wire on a commercial branch circuit

    • MC cable — faster to pull (single-pass), fewer boxes, works well through T-bar ceilings. Best on interior commercial branch circuits (offices, retail, tenant fit-outs) where the environment is dry and the routing is flexible. Typically 30–40 % faster labor than conduit-and-wire.
    • Conduit and wire (EMT + THWN-2) — required in most hospitals, high-hazard occupancies, and any wet environment. Higher fill flexibility, easier future re-pulls, and the panel-shop can pre-pull wire into conduit runs before enclosure delivery.
    • Hospital / patient-care exception — NEC 517.13(A) requires MC-HCF (health-care facility) or conduit with an equipment-grounding conductor of the type in 250.118(A) — no standard MC in patient-care areas.

    Mill vendors — Southwire, Encore, Cerrowire, General Cable

    Four US-domestic wire mills own the mainstream building-wire supply. All four are BABA / Buy-America compliant on their US-manufactured lines. Pricing changes daily with copper and aluminum spot; PES publishes a Monday-morning pricing sheet for the top 40 SKUs across all four mills.

    Mill US manufacturing footprint Strongest line PES stock depth
    Southwire Carrollton GA (HQ), Hartselle AL, McMinnville TN, +10 US plants SIMpull THHN, MC-Cable, Romex Deep on all sizes 14–1000 kcmil
    Encore Wire McKinney TX (HQ, one massive campus) Value-tier THHN and XHHW-2 in high volume Deep on 14 AWG – 500 kcmil
    Cerrowire Hartselle AL (HQ), Ogden UT Residential Romex + THHN in short-put-up reels Deep on 14–10 AWG cut-lengths
    General Cable / Prysmian Highland Heights KY (HQ), 10 US plants MC cable, tray cable, industrial specialty Cut-to-length and full reels
    Priority Wire & Cable Little Rock AR (HQ), distribution nationwide URD, USE-2 direct burial, industrial Full reels for underground service
    Nassau National Cable Long Island NY Specialty — PV, medium-voltage, tray cable Special-order

    Conduit types — EMT, IMC, RMC, PVC (40/80), FMC, LFMC

    Conduit choice is a function of environment (indoor / outdoor / burial / hazardous), physical protection required (labor-space vs machine-shop vs bomb-hard), and cost. Each type has a specific NEC article that governs its use — 358 for EMT, 342 for IMC, 344 for RMC (galvanized rigid), 352 for PVC, 348 for FMC, and 356 for LFMC/LFNC.

    Type NEC article Wall thickness Best for Trade sizes stocked
    EMT (electrical metallic tubing) 358 Thin-wall steel Interior dry / damp, exposed 1/2" – 4"
    IMC (intermediate metal) 342 Medium-wall steel Outdoor, general commercial, direct burial with fitting 1/2" – 4"
    RMC / GRC (galvanized rigid) 344 Heavy-wall steel Outdoor, direct burial, hazardous locations, physical protection 1/2" – 6"
    PVC Schedule 40 352 PVC, medium wall Underground, wet, direct-burial-approved (with markings) 1/2" – 6"
    PVC Schedule 80 352 PVC, heavy wall Underground with physical exposure, exposed outdoor risers 1/2" – 6"
    FMC (flexible metal) 348 Interlocked steel Interior fixture whips, motor terminations (dry) 3/8" – 4"
    LFMC (liquid-tight flex metal) 350 PVC over interlocked steel Motor terminations, wet, oily, or vibrating 3/8" – 4"
    LFNC (liquid-tight non-metallic) 356 PVC only Motor terminations in corrosive environments 3/8" – 2"

    ⚠ PVC Schedule 40 direct-burial marking: not all Sch 40 is DB-approved.

    Only PVC conduit marked with the specific application (e.g., 'Type DB', 'Type EB', or 'Type A' for above-ground) is direct-burial listed for that use. Underground raceway typically uses Type DB120 (a specific wall-thickness class between Sch 40 and Sch 80) or Sch 40 marked 'For Above and Below Ground Use'. Check the printed jacket text before you drop conduit in a trench.

    Conduit trade-size selection for a common feeder pull

    • Three 4/0 THWN-2 (2/0 EGC) in a 200 A feeder — per NEC Chapter 9 Table 5 cross-section: 4/0 THWN-2 = 0.3117 in², 2/0 EGC = 0.2223 in². Three 4/0 + one 2/0 total = 1.16 in². Under NEC Table 4 (40 % fill for over 2 conductors), 2" EMT (1.34 in² max fill) is the smallest that works. Round up to 2-1/2" if pull length exceeds 100 ft with more than three 90° bends.
    • Use the PES conduit fill calculator for any mixed-conductor pull — enter each conductor and insulation type, and the tool returns the smallest trade size (EMT / IMC / RMC / PVC) that stays under 40 % fill.

    How to spec wire and conduit for a 200 A underground service lateral

    Confirm utility requirements for the lateral

    Every utility publishes trench depth, warning tape requirements, and the wire type. LG&E wants USE-2 (or URD) at 30 in cover, red warning tape 12 in above. Duke often accepts THWN-2 in Schedule 40 PVC at 24 in cover. Match the local standard exactly.

    Pick the wire — USE-2 direct-buried or THWN-2 in PVC

    For 200 A: 2/0 Cu USE-2 (direct burial) or 4/0 Al USE-2 works at the 83 % rule per NEC 310.12. If pulling in conduit, spec 2/0 Cu THWN-2 or 4/0 Al XHHW-2.

    Pick the conduit — PVC Sch 40 or Sch 80 for the riser

    PVC Schedule 40 (DB-listed) for the horizontal underground run. Schedule 80 for the vertical riser out of grade (physical-damage protection required by NEC 300.5(D)). Common 200 A underground service uses 2-1/2" PVC — or 3" PVC if pulling 4/0 Al in with an EGC and a communications sub-duct.

    Add warning tape and depth of cover

    Trench 24 in (Duke, most Southeast) or 30 in (LG&E, some Northeast) minimum cover, backfill 6" of sand around the pipe, then red warning tape 12 in above the pipe, then compact backfill. Utility inspects the open trench before backfill.

    Grounding electrode conductor sizing

    For 2/0 Cu service: #4 Cu bare GEC to two ground rods (or Ufer). For 4/0 Al: #2 Cu GEC. Table 250.66 sets the size by service-entrance conductor.

    Meter socket + main disconnect at the building

    See the load-center + meter-combo selector page for utility-approved sockets. Milbank U5140-XL-K3L is the LG&E standard for 200 A residential.

    Frequently asked questions

    Can I use THHN in outdoor conduit?

    Only if the printed jacket text includes THWN-2 as a dual rating. Straight THHN (no THWN-2 marking) is not permitted in wet locations, and any raceway outdoors, in a slab, or underground counts as a wet location under NEC 300.5(B) / 300.9. Modern building wire from Southwire, Encore, and Cerro is almost always dual-marked THHN/THWN-2, but always verify the print.

    What's the difference between XHHW and XHHW-2?

    XHHW is rated 90 °C dry, 75 °C wet. XHHW-2 is rated 90 °C dry and 90 °C wet — the extra ampacity in wet locations matters on feeders and service conductors. Modern spec is XHHW-2 for anything over #6 AWG.

    Do you cut wire to length or ship full reels?

    Both. Cut-to-length starts at 100 ft and is charged per-foot at your contract price plus a small cut fee. Full reels (1000 ft, 2500 ft) get the mill-reel price with no cut fee. For anything over 5000 ft, we usually direct-ship from the mill — Southwire Carrollton, Encore McKinney, or Cerro Hartselle — at contractor pricing with the mill freight passed through.

    Do you carry aluminum service-entrance conductor?

    Yes — 4/0 Al XHHW-2, 250 kcmil, 350 kcmil, 500 kcmil, and 750 kcmil in Southwire and Encore. Aluminum is roughly half the copper price per amp for feeders and service — most residential and light commercial service laterals in Kentucky are 4/0 Al XHHW-2 or 250 kcmil Al.

    What's the difference between EMT and IMC?

    EMT is thin-wall steel — cheapest, lightest, fastest to install, but not rated for direct burial and not the best for physical protection. IMC is medium-wall — heavier and stiffer than EMT, rated for outdoor and (with appropriate fitting) direct burial. RMC (rigid galvanized) is the heaviest — required for hazardous locations and any run needing serious impact protection. Cost per foot roughly EMT : IMC : RMC = 1 : 1.7 : 2.5.

    Do PES stock BABA / Buy America wire and conduit?

    Yes. Southwire USA-manufactured lines, Encore (all-US McKinney TX), Cerro (US Hartselle AL), Wheatland (US-melted steel conduit), Republic Conduit (US-melted steel), and JM Eagle / Cantex / Carlon PVC are all BABA-compliant. Request the certification packet at quote time for federal / DOT / utility work.

    What's the ampacity of 4/0 Cu THWN-2 at 30 °C ambient in 3 CCC in 2" EMT?

    From NEC Table 310.16, 4/0 Cu THWN-2 at 75 °C column = 230 A base. Three current-carrying conductors in the raceway = no derate under Table 310.15(C)(1). At 30 °C ambient, no temperature derate. Final ampacity = 230 A. Perfect for a 200 A service (using the 83 % rule per NEC 310.12, the 200 A service actually only needs 2/0 Cu THWN-2 = 175 A × 1.20 ampacity increase per 310.12).

    Related PES Distribution guides

    Sibling PES pillar guides

    Related PES Distribution guides

    Registered contractors — free calculators on the axis.pesdistribution.com portal

    Register for the PES contractor portal → Free. Verified electrical contractors only.

    Order wire and conduit at contractor pricing

    Southwire, Encore, Cerrowire, General Cable, and Priority Wire — cut-to-length or full-reel. Wheatland, Allied, Republic, JM Eagle, Cantex, and Carlon conduit — 1/2" through 6", all trade sizes.

    Register for contractor pricing

    Need Help Sizing This?

    Our team can help you calculate loads, select the right equipment, and source everything from one PO.

    📞 (502) 790-0600

    Email Our Team
    Solar Panels Generators Batteries / ESS EV Chargers Circuit Breakers Charge Controllers

    One PO. One Invoice. Every Trade Covered.

    PES Supply is the distribution arm of PES Global Group — 50,000+ SKUs from 169 authorized brands, LTL freight shipping from Louisville, KY.

    Get a Quote
    Share: X f in @

    Related Articles

    Generator Install Specification Guide for Electricians

    Generator Install Specification Guide for Electricians

    Sep 01, 2026
    EV Charger Installer Certification Guide

    EV Charger Installer Certification Guide

    Sep 01, 2026
    Industrial Cabinet + Enclosure Selection Guide

    Industrial Cabinet + Enclosure Selection Guide

    Sep 01, 2026
    Service Entrance Equipment Multi-Brand Comparison

    Service Entrance Equipment Multi-Brand Comparison

    Sep 01, 2026
    Motor Control Selector for Electrical Contractors

    Motor Control Selector for Electrical Contractors

    Sep 01, 2026
    Commercial Panel Upgrade Contractor Guide

    Commercial Panel Upgrade Contractor Guide

    Sep 01, 2026
    Louisville Electrical Contractor Supply Guide

    Louisville Electrical Contractor Supply Guide

    Sep 01, 2026
    Electrical Contractor NEC Code Compliance Library

    Electrical Contractor NEC Code Compliance Library

    Sep 01, 2026
    Level 2 vs DCFC site-fit selection chart by dwell time — PES Supply

    Level 2 vs DCFC Charger Selection for Commercial Sites: T...

    Sep 01, 2026
    EV load management demand curve — 6-port L2 on a constrained service — PES Supply

    Load Management for EV Charging Sites: The Engineer's Fie...

    Sep 01, 2026
    ChargePoint vs Wallbox vs Enphase IQ EV charger comparison matrix — PES Supply

    ChargePoint vs Wallbox vs Enphase IQ EV Charger: 2026 L2 ...

    Sep 01, 2026
    Commercial fleet electrification 5-year TCO by vehicle class — PES Supply

    Commercial EV Fleet Electrification Buyer Guide: TCO, Inf...

    Sep 01, 2026
    NEVI compliance requirements matrix — PES Supply

    NEVI Compliance for EV Charging Deployments: The 2026 Fie...

    Sep 01, 2026
    EV charging site-prep installed cost breakdown — PES Supply

    EV Charging Site-Prep Distributor Guide: The Whole BOM, N...

    Sep 01, 2026
    PES Supply contractor consumables and electrical accessories

    Contractor Tool Buying Guide 2026: Cordless Platforms, Te...

    Sep 01, 2026
    PES Supply contractor consumables and electrical accessories

    Contractor Safety and PPE Buying Guide 2026: Arc Flash, F...

    Sep 01, 2026
    PES Supply contractor consumables and electrical accessories

    Fasteners and Anchors for Electrical Installations: Contr...

    Sep 01, 2026
    PES Supply contractor consumables and electrical accessories

    Contractor Consumables Subscription Program: Auto-Reorder...

    Sep 01, 2026
    PES Supply pallet deals — 179 wholesale SKUs by category

    Pallet Deals + Wholesale Bulk Pricing — Contractors, Inst...

    Sep 01, 2026
    PES Supply LED lighting distributor matrix — 357 SKUs across 13 brands

    LED Lighting Distributor: Lithonia, Cooper, Hubbell, RAB,...

    Sep 01, 2026
    Motor control selector — NEMA starter size vs HP, VFD family ranges (Schneider, Eaton, Siemens)

    Motor Control: Starters, VFDs, Contactors — Square D 8536...

    Sep 01, 2026
    Load center + meter combo selector — amp rating and utility approval matrix

    Load Center + Meter Combo Selector: Residential Meter Mai...

    Sep 01, 2026
    Circuit breaker interrupting rating comparison — Square D, Eaton, Siemens, GE residential and commercial

    Circuit Breakers: Square D vs Eaton vs Siemens vs GE — QO...

    Sep 01, 2026
    PES Distribution — 5-brand electrical supply matrix (Square D, Eaton, GE, Siemens, Schneider Electric)

    Electrical Distribution: Breakers, Panels, Wire & Conduit...

    Sep 01, 2026
    NEC 240.6 standard circuit breaker sizes chart — PES Supply

    Standard Circuit Breaker Sizes: NEC 240.6 Chart (15A to 6...

    Aug 30, 2026
    Electrical Conduit Types: PVC vs. EMT vs. RMC for Solar Installations

    Electrical Conduit Types: PVC vs. EMT vs. RMC for Solar I...

    Jul 31, 2026
    Surge Protection for Solar Systems: SPD Sizing and Installation Guide

    Surge Protection for Solar Systems: SPD Sizing and Instal...

    Jul 31, 2026
    NEC Wire Sizing Guide: Ampacity Charts for Solar and Generator Installations

    NEC Wire Sizing Guide: Ampacity Charts for Solar and Gene...

    Jul 31, 2026
    Conduit Fill Chart: Max THHN Conductors per EMT Size (NEC)

    Conduit Fill Chart: Max THHN Conductors per EMT Size (NEC)

    Jul 22, 2026
    Wire Ampacity Chart (NEC 310.16): Copper & Aluminum by Gauge

    Wire Ampacity Chart (NEC 310.16): Copper & Aluminum by Gauge

    Jul 22, 2026
    Standard Breaker Sizes Chart (NEC): Breaker-to-Wire Sizing Guide

    Standard Breaker Sizes Chart (NEC): Breaker-to-Wire Sizin...

    Jul 22, 2026
    Solar Grounding and Bonding Guide: NEC 690.43, 250, and Lightning Protection

    Solar Grounding and Bonding Guide: NEC 690.43, 250, and L...

    May 15, 2026
    Solar Disconnect and Overcurrent Protection Guide: NEC 690 Requirements Explained

    Solar Disconnect and Overcurrent Protection Guide: NEC 69...

    Apr 15, 2026
    Solar Wire and Cable Guide: PV Wire vs USE-2 vs THHN — Sizing, Selection, and NEC Compliance

    Solar Wire and Cable Guide: PV Wire vs USE-2 vs THHN — Si...

    Mar 15, 2026
    Solar Permitting Guide: NEC Requirements, AHJ Approval Process, and Inspection Checklist

    Solar Permitting Guide: NEC Requirements, AHJ Approval Pr...

    Feb 15, 2026
    NEC 2026 Effective: Top Changes Solar Installers Must Implement Now

    NEC 2026 Effective: Top Changes Solar Installers Must Imp...

    Jan 15, 2026
    NEC 2026 Preview: Key Code Changes Solar Installers Need to Prepare For

    NEC 2026 Preview: Key Code Changes Solar Installers Need ...

    Apr 15, 2025
    Cantex junction boxes, electrical fittings, and Portlandia Electric Supply branding for infrastructure safety.

    From Safety to Efficiency: The Role of Cantex Inc.'s Elec...

    Apr 13, 2025

    Get Price Drops & Product Releases

    Weekly digest for installers and project managers — price drops, new stock, NEC code updates.

    PES Supply, a PES Global Group Company